Description

The CV doesn't simulate correctly the WCET configured for a function. In an example with one function with a single cyclic interface (period 10ms, wcet 5ms), the simulation shows task activation with duration longer than 5ms.

Additional Information

See attached e-mails.

TagsNo tags attached.
Attached Fileszip file icon emails.zip [^] (1,566,665 bytes) 2019-05-27 10:25

- Relationships

-  Notes
(0003673)
ellidiss (developer)
2019-11-09 15:51

As explained by the discussion in the attached email, the problem comes from the Vertical Transformation.
The WCET (Compute_Execution_Time) is well generated at IV level.